Communication of signal and voice between cage and hoistman
Modular design, serial transmission 2.4 kbd, FFSK, hamming distance D = 4, UART frames
Single stroke, emergency, destination keys, start to move, lock switch, limit switch, door switch, slack rope switch
Analogue signal for rope tension
Depth indication in the cage
Total voice communication in the shaft
components and short info
| Designation: Union catalog
Type: MR90
Type of protection: - | | | |
| Designation: Loudspeaker
Type: iLA3/..
Type of protection: I M 1 EEx ia I | | | |
| Designation: LF Interface
Type: NFT01-1
Type of protection: I M 1 Ex ia I | | | |
| Designation: i/i Coupling Module
Type: iKO02
Type of protection: I M 1 EEx ia I | | | |
| Designation: Antenna Interface
Type: AANT01-1
Type of protection: I M 1 Ex ia I | | | |
| Designation: Antenna
Type: ANTM03/2 - HFI01
Type of protection: I M 1 Ex ia I | | | |
| Designation: Antenna
Type: ANTM03/3
Type of protection: I M 1 Ex ia I | | | |
| Designation: RF Isolator
Type: HFU01
Type of protection: I (M1) [EEx ia] I | | | |
| Designation: Radio Data Modem
Type: MOD 02
Type of protection: I M 1 EEx ia I | | | |
| Designation: RF Transmitter
Type: HFS..
Type of protection: I M1 EEx ia I | | | |
| Designation: RF Receiver
Type: HFE..
Type of protection: I M 1 EEx ia I | | | |
| Designation: Splitter
Type: MRSP01
Type of protection: I M1 EEx ia I | | | |
| Designation: Radio Station
Type: MRST3..
Type of protection: I M2 EEx ib I | | | |
| Designation: RF cable
Type: KK02
Type of protection: | | | |
end faq